Model No.︰DGA-200F
Brand Name︰DukeTech
Country of Origin︰China
Unit Price︰US $ 1 / set
Minimum Order︰1 set
Technical requirements
Transformer online monitoring and fault diagnosis technology is of great significance to improve the safety and stability of the power system.The online monitoring technology based on the analysis of dissolved gases in oil is the most common and most important technology in online monitoring of transformers. The analysis of the composition and content of dissolved gases in oil is one of the most effective measures to monitor the safe operation of oil-filled electrical equipment.The use of photoacoustic spectroscopy to analyze dissolved gases in oil to monitor the operation of oil-filled electrical equipment has the characteristics of maintenance-free, high real-time and high precision.
Technology
The DKG-200F oil gas analyzer can realize gas analysis in multi-component oil, and the high-sensitivity measurement of short-path optical path can be realized by Finnish interference company's photoacoustic spectroscopy technology. Ultra-high sensitivity based enhanced cantilever beam Optical microphone technology enables linear dynamic range ratios up to 5 steps. Ultra-high sensitivity is achieved with 7 optical narrow-band filters. Extremely narrow optical filtering removes background gas interference; multiple spectral regions can be beneficial The smallest cross-sensitivity. The multi-gas analyzer is based on infrared photoacoustic spectroscopy technology. It has a pulsed infrared light source and passes through a narrow-band optical filter to form seven spectral bands in the mid-infrared region for gas analysis.
Characteristic
Technical parameter
Technical specifications |
|
||||
Range |
|
||||
Gas |
Lower limit / ppm |
Upper limit / ppm |
|
||
Hydrogen |
5 |
5,000 |
|
||
Methane |
1 |
50,000 |
|
||
Ethane |
1 |
50,000 |
|
||
Ethylene |
1 |
50,000 |
|
||
Acetylene |
1 |
50,000 |
|
||
Carbon monoxide |
5 |
50,000 |
|
||
Carbon dioxide |
5 |
50,000 |
|
||
Oxygen |
0% |
100% |
|
||
Nitrogen |
0% |
100% |
|
||
Moisture measurement with micro water |
0% |
100% |
|
||
Physical and mechanical |
|
||||
Ambient operating temperature |
+5 - +50℃ |
|
|||
Operating sample temperature |
0 - +45℃ |
|
|||
Storage temperature |
-30°C - +80℃ |
|
|||
Humidity |
90% (non-condensing @30℃) |
|
|||
Vibration tolerance |
IEC 60068-2-6, Fc test |
|
|||
Drop/Shock |
Iec 60068-2-31 and ista 1a |
|
|||
Main power input frequency range |
47-63Hz |
|
|||
Main power input voltage range |
Universal 90-250vac |
|
|||
Weight |
< 15kg |
|
|||
Size |
48.4cmW x 13.9cmH x 44cmD (19.1In W x 5.5 in H x 17.3 in D) |
|
|||
Gas chamber volume |
< 30ml |
|
|||
Oil volume in the extraction unit |
<= 50ml |
|
|||
Dynamic range |
500-50,000 |
|
|||
Zero drift |
± detection limit / 1 month |
|
|||
Measurement repeatability |
5% of the measured value under reference conditions |
|
|||
Range drift |
5% of measured value / 12 months |
|
|||
Precision |
+/- 5% or +/- 2 ppm (whichever is greater) +/-1% rh (H2O relative humidity is 0-90%) |
|
|||
standard |
|||||
EN61326-1:2006 |
Radiation emission (A level ) |
||||
EN61326-1:2006 |
Conducted emission (A level) |
||||
EN61000-3-2:2000 |
Steady state and wave harmonics |
||||
EN61000-3-3:2001 |
Flicker test |
||||
IEC61000-4-2:2001 |
Electrostatic discharge immunity test |
||||
IEC61000-4-3:2002 |
Radiation immunity |
||||
IEC61000-4-4:2001 |
Fast electrical transient/burst immunity test |
||||
IEC61000-4-5:2001 |
Surge immunity |
||||
IEC61000-4-6:2001 |
Conducted radio frequency immunity |
||||
IEC61000-4-8:2001 |
Magnetic field immunity |
||||
IEC61000-4-11:2001 |
Voltage dips and interruptions |
||||
Other |
EN 61010-1:2001 IEC61010-1 UL61010-1 CAN/CSA-C22.2 No.61010-1 EN 50270:2006 |
Payment Terms︰ TT/LC/Paypal